Applications
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75 ºC maximum for polyethylene Insulation or 90 ºC maximum for crosslinked insulation.
Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC neutral messenger.
Standards
• B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
• Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
Ampacity
To determine correct ampacity by conductor size, please consult the National Electric Code, Latest edition.
Item # |
Phase
|
Phase
|
Phase
|
Bare
|
Bare
|
Bare
|
Weight
|
Weight
|
Ampacity
|
Ampacity
|
---|---|---|---|---|---|---|---|---|---|---|
Murex |
Phase Conductor Size/AWG N/A 1/0 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness (mls) N/A 60 |
Bare Neutral Messenger Size/AWG N/A 1/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 1990 |
Weight Per MFT XLP (lbs/MFT) N/A 395.1 |
Weight Per MFT Poly (lbs/MFT) N/A 369.4 |
Ampacity XLP (Amps) N/A 205 |
Ampacity Poly (Amps) N/A 160 |
Purpura |
Phase Conductor Size/AWG N/A 1/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness (mls) N/A 60 |
Bare Neutral Messenger Size/AWG N/A 1/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 1990 |
Weight Per MFT XLP (lbs/MFT) N/A 386.1 |
Weight Per MFT Poly (lbs/MFT) N/A 369.4 |
Ampacity XLP (Amps) N/A 205 |
Ampacity Poly (Amps) N/A 160 |
Clam |
Phase Conductor Size/AWG N/A 2 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness (mls) N/A 45 |
Bare Neutral Messenger Size/AWG N/A 2 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 1350 |
Weight Per MFT XLP (lbs/MFT) N/A 243.2 |
Weight Per MFT Poly (lbs/MFT) N/A 229.2 |
Ampacity XLP (Amps) N/A 150 |
Ampacity Poly (Amps) N/A 120 |
Nassa |
Phase Conductor Size/AWG N/A 2/0 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness (mls) N/A 60 |
Bare Neutral Messenger Size/AWG N/A 2/0 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 2510 |
Weight Per MFT XLP (lbs/MFT) N/A 485.8 |
Weight Per MFT Poly (lbs/MFT) N/A 455.3 |
Ampacity XLP (Amps) N/A 235 |
Ampacity Poly (Amps) N/A 185 |
Melita |
Phase Conductor Size/AWG N/A 3/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness (mls) N/A 60 |
Bare Neutral Messenger Size/AWG N/A 3/0 |
Bare Neutral Messenger Stranding N/A 19 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 3310 |
Weight Per MFT XLP (lbs/MFT) N/A 585.2 |
Weight Per MFT Poly (lbs/MFT) N/A 562.9 |
Ampacity XLP (Amps) N/A 275 |
Ampacity Poly (Amps) N/A 215 |
Nannynose |
Phase Conductor Size/AWG N/A 336.4 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness (mls) N/A 80 |
Bare Neutral Messenger Size/AWG N/A 336.4 |
Bare Neutral Messenger Stranding N/A 19 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 6146 |
Weight Per MFT XLP (lbs/MFT) N/A 1160.4 |
Weight Per MFT Poly (lbs/MFT) N/A 1118.0 |
Ampacity XLP (Amps) N/A 420 |
Ampacity Poly (Amps) N/A 325 |
Fusus |
Phase Conductor Size/AWG N/A 4 |
Phase Conductor Stranding N/A Solid |
Phase Conductor Insulation Thickness (mls) N/A 45 |
Bare Neutral Messenger Size/AWG N/A 4 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 881 |
Weight Per MFT XLP (lbs/MFT) N/A 151.9 |
Weight Per MFT Poly (lbs/MFT) N/A 147.6 |
Ampacity XLP (Amps) N/A 115 |
Ampacity Poly (Amps) N/A 90 |
Oyster |
Phase Conductor Size/AWG N/A 4 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness (mls) N/A 45 |
Bare Neutral Messenger Size/AWG N/A 4 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 881 |
Weight Per MFT XLP (lbs/MFT) N/A 161.8 |
Weight Per MFT Poly (lbs/MFT) N/A 151.7 |
Ampacity XLP (Amps) N/A 115 |
Ampacity Poly (Amps) N/A 90 |
Portunus |
Phase Conductor Size/AWG N/A 4/0 |
Phase Conductor Stranding N/A 19/w |
Phase Conductor Insulation Thickness (mls) N/A 60 |
Bare Neutral Messenger Size/AWG N/A 4/0 |
Bare Neutral Messenger Stranding N/A 19 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 4020 |
Weight Per MFT XLP (lbs/MFT) N/A 723.9 |
Weight Per MFT Poly (lbs/MFT) N/A 697.3 |
Ampacity XLP (Amps) N/A 315 |
Ampacity Poly (Amps) N/A 245 |
Haiotis |
Phase Conductor Size/AWG N/A 6 |
Phase Conductor Stranding N/A Solid |
Phase Conductor Insulation Thickness (mls) N/A 45 |
Bare Neutral Messenger Size/AWG N/A 6 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 563 |
Weight Per MFT XLP (lbs/MFT) N/A 102.5 |
Weight Per MFT Poly (lbs/MFT) N/A 98.8 |
Ampacity XLP (Amps) N/A 85 |
Ampacity Poly (Amps) N/A 70 |
Patella |
Phase Conductor Size/AWG N/A 6 |
Phase Conductor Stranding N/A 7/w |
Phase Conductor Insulation Thickness (mls) N/A 45 |
Bare Neutral Messenger Size/AWG N/A 6 |
Bare Neutral Messenger Stranding N/A 7 |
Bare Neutral Messenger Breaking Strength (lbs/MFT) N/A 563 |
Weight Per MFT XLP (lbs/MFT) N/A 109.1 |
Weight Per MFT Poly (lbs/MFT) N/A 101.6 |
Ampacity XLP (Amps) N/A 85 |
Ampacity Poly (Amps) N/A 70 |