  • MC Cable

    Applications
    Classic Wire Type MC Cable is primarily used for services, feeders, and branch circuits as specified in the 2011 National Electric Code. Type MC cable with Type XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C.  Used for power and lighting indoors, exposed or concealed, in cable tray where identified for such use; in a raceway, or in dry locations and embedded in plaster or against other masonry.  Voltage rating for XHHW-2 conductors is 600V.

    Construction
    Compact stranded AA-8000 series aluminum conductor material per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable. A binder tape is wrapped over the conductors with interlocked aluminum tape applied over the assembly. Rated 90°C wet or dry and is flame and sunlight resistant. XLPE insulated XHHW-2 conductors and insulated grounding conductor surrounded with aluminum armor (Metal Clad).

    Specifications
    Classic Wire  Type MC cable with Type XHHW-2 conductors are manufactured and tested in accordance with the latest revisions of:

    • UL 44 for Thermoset-Insulated Wires and Cables
    • UL 83 for Thermoplastic-Insulated Wires and Cables
    • UL 1479 Standard for Fire Tests of Through-Penetration Firestops.
    • UL Classified 1, 2, and 3 Hour Through-Penetration Firestop Systems.
    • UL 1569 for Metal-Clad Cables.
    • IEEE 1202 - Flame Testing of Cables for Use in Cable Tray, in Industrial and Commercial Occupancies (70,000 BTU/hr).
    • ICEA T-29-520 - Vertical Cable Tray Flame Tests (210,000 Btu/hr).
    • ICEA S-66-524 and requirements of the National Electric Code
    • ICEA S-95-658 (NEMA WC 70) construction requirements
    • Federal Specification J-C-30B

    Color Code 
    Three Phase Conductors (3):  Black, red, white
    Ground Conductor (1):  Green

    Other colors and stripes available by special order.


    For Special Order

    • The entire assembly can be covered with a PVC or CPE outer jacket (black or color).  Jacketed MC Cable may be used in wet locations, either direct burial, in underground conduit, or overhead. 
    • Halogen free jackets are available upon request
    • A black jacket (on individual conductors) with color stripes can be requested.
    • Bare Ground conductor available upon request.
    • For sizes not listed above please contact sales.

    Ampacity
    To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

     

  • MC Cable

    Applications
    Classic Wire Type MC Cable is primarily used for services, feeders, and branch circuits as specified in the 2011 National Electric Code. Type MC cable with Type XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C.  Used for power and lighting indoors, exposed or concealed, in cable tray where identified for such use; in a raceway, or in dry locations and embedded in plaster or against other masonry.  Voltage rating for XHHW-2 conductors is 600V.

    Construction
    Compact stranded AA-8000 series aluminum conductor material per ASTM B800, ASTM B801, ASTM B836, ASTM B901 (Single Input Wire), as applicable. A binder tape is wrapped over the conductors with interlocked aluminum tape applied over the assembly. Rated 90°C wet or dry and is flame and sunlight resistant. XLPE insulated XHHW-2 conductors and insulated grounding conductor surrounded with aluminum armor (Metal Clad).

    Specifications
    Classic Wire  Type MC cable with Type XHHW-2 conductors are manufactured and tested in accordance with the latest revisions of:

    • UL 44 for Thermoset-Insulated Wires and Cables
    • UL 83 for Thermoplastic-Insulated Wires and Cables
    • UL 1479 Standard for Fire Tests of Through-Penetration Firestops.
    • UL Classified 1, 2, and 3 Hour Through-Penetration Firestop Systems.
    • UL 1569 for Metal-Clad Cables.
    • IEEE 1202 - Flame Testing of Cables for Use in Cable Tray, in Industrial and Commercial Occupancies (70,000 BTU/hr).
    • ICEA T-29-520 - Vertical Cable Tray Flame Tests (210,000 Btu/hr).
    • ICEA S-66-524 and requirements of the National Electric Code
    • ICEA S-95-658 (NEMA WC 70) construction requirements
    • Federal Specification J-C-30B

    Color Code 
    Four Phase Conductors (4):  Black, red, blue, white
    Grounding Conductor (1):  Green

    Other colors and stripes available by special order.


    For Special Order

    • The entire assembly can be covered with a PVC or CPE outer jacket (black or color).  Jacketed MC Cable may be used in wet locations, either direct burial, in underground conduit, or overhead. 
    • Halogen free jackets are available upon request
    • A black jacket (on individual conductors) with color stripes can be requested.
    • Bare Ground conductor available upon request.
    • For sizes not listed above please contact sales.

    Ampacity
    To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.

     